Description

Scope of this activity is to perform a gap analysis on the current status of EdgeX microservices and deliver specific market requirements to other Working Groups.


Requirements

As part of the gap analysis, common requirements in Oil&Gas will be taken into account.


Design

AreaMicroserviceGaps IdentifiedCriticalityWhy ImportantRecommended Actions
DeviceOPC UANew installations of SCADA systems are typically expected to be compliant with the OPC UA standard

HIGH



DeviceOPC DAAlthough OPC UA is an emerging standard, E&P Companies are still massively using OPC DA in legacy systems and in some cases in new installations as well

HIGH



DeviceModbusSeems like the way the current Modbus

HIGH



DeviceZigbee

MEDIUM



DeviceLoRa



DeviceGPS



DeviceProfinetSiemens hardware is used in many Oil&Gas installations (e.g. North Sea) and Profinet I/O would be a suitable protocol for interfacing with EdgeX

MEDIUM



DeviceOpenDDS



CoreData



CoreMetadata



CoreCommand



SupportRules Engine / Analytics



SupportScheduling



SupportAlerts & Notifications



SupportLoggingNeed to be able to specify persistency policies as logs are required to be assessed as per safety incidents


ExportClient Registration & Distribution



SystemSystem ManagementConnection loss handling: changes made while offline will be cached and sent when connection is re-established


SecuritySecurityNeed to lock down access to APIs from remote hosts not authenticated



Code

If specific code addressing some of the identified gaps will be implemented as part of this project, the contributor will submit a PR on the relevant github repository.


Current status

Waiting on v0.5 release.

A preliminary document was shared here EdgeX-Foundry-Oil&Gas-v3.pdf